DicomObjects Reference
DicomObjects Reference / DicomDataSet Object / Send Method
Network address (as dotted notation or resolvable name) to which the image is to be sent.
Port on which remote application is listening.
Name of remote Application Entity.
Name to quote for this Application Entity
In This Topic
    Send Method
    In This Topic
    Description
    Sends a DataSet to a remote DICOM application
    Syntax
    Visual Basic
    Public Function Send( _
       ByVal Node As String, _
       ByVal Port As Integer, _
       ByVal CallingAE As String, _
       ByVal CalledAE As String _
    ) As Long
    Parameters
    Node
    Network address (as dotted notation or resolvable name) to which the image is to be sent.
    Port
    Port on which remote application is listening.
    CallingAE
    Name of remote Application Entity.
    CalledAE
    Name to quote for this Application Entity
    Remarks
    This method negotiates an association, sends one image/dataset over it, and then closes it.  DICOM does not allow SCPs to draw any conclusions about the relationships between images based on the opening and closing of associations, so this should never be a problem (apart from slight network inefficiency).  However, there are several badly written applications in the world, which incorrectly assume that the end of an association indicates the end of a series or a study etc., and if interfacing to such a faulty implementation, it is possible to send multiple images on one association by using a DicomConnection object, and its SendImages method.